Rheem Recalls to Repair Oil-Fired Furnaces Due to Fire Hazard

Type: Recall
Equipment: Furnace
Recall or Alert Date: 01-22-2009
Serial Number: 09-104
Brands Affected: RheemRuud

Description of Problem:

If the furnace is not properly wired, the oil burner can continue to operate when the blower shuts off, posing a fire hazard to consumers. Rheem has received one report in which the furnace was incorrectly wired. No injuries or property damage have been reported.

Affected Products:

This recall involves oil-fired furnaces sold under the Rheem, Ruud and United Refrigeration brands. Only the models beginning with the model numbers listed in the chart below and with date codes ending in 0106 through 5206, 0107 through 5207, or 0108 through 4808 are included in this recall. The model number and date code (designated by the four digits following an “M” in the middle of the serial number) are printed on the unit’s rating plate, which is on the left wall of the furnace’s interior just above the burner. The rating plate can be found by opening the unit’s burner access door, which has slotted openings.

Model # Brand & Description
ROBF Rheem Classic/Ruud Achiever High Efficiency Upflow Oil Furnace
ROPF Rheem Classic/Ruud Achiever High Efficiency Downflow/Horizontal Oil Furnace
TZOUP United Refrigeration “Thermal Zone” Upflow Oil Furnace
TZODH United Refrigeration “Thermal Zone” Downflow/ Horizontal Oil Furnace