Description of Problem:

We have had a few reports of nuisance pressure switch tripping on Amana® brand 90% (ACV9070CXA, ACV90905DXA*) counterflow model furnaces.

Our investigation of the issue has determined the problem to be due to length of the pressure switch hose from the ID Blower to ID Blower Pressure Switch sagging. In order to address this issue, we reduced the pressure switch hose length to prevent sagging, which could trap moisture in the hose and cause nuisance tripping of the pressure switch.

Affected Products:

Amana Furnace ACV9070CXA, ACV90905DXA*

Source:

Amana